Browse Categories

Search in Category

Sample Lines, Pumps, and Tubes

Browse Categories

Loading...

Sample Lines, Pumps, and Tubes

Gas Detection/Sample Lines, Pumps, and Tubes 
Viewing Page 23 of 25 (248 results)

Draeger, Inc. - DRA 6727101 - DT Sulfur Dioxide 0.1/a (10)

Items #: DRA 6727101

Product Specific Information; Dräger Tubes - Sulphur Dioxide 0.1/a, Short Term Tubes, 10 tests per box, Draeger P/N 6727101 Standard Measuring Range : 0.1 to 3 ppm Number of Strokes (n) : 100 Time for Measurement : app. 20 min Standard Deviation : ± 10 to 15 % Colour Change : yellow -> orange Ambient Operating Conditions Temperature : 10 to 30 °C Absolute Humidity : 3 to 15 mg H2O / L Reaction Principle SO2 + Na2[HgCI4] + Methyl red -> Na2[Hg(SO3)2] + 4 HCI Cross Sensitivity It is impossible to measure sulphur dioxide in the presence ofother acidic gases.
Call For Availability
UOM : BX
$105.00


Add to Quote
Previous Purchase
Call For Availability
UOM : BX
$93.00


Add to Quote
Previous Purchase
Call For Availability
UOM : ST
$102.00


Add to Quote
Previous Purchase
Call For Availability
UOM : BX
$105.00


Add to Quote
Previous Purchase
Call For Availability
UOM : BX
$95.00


Add to Quote
Previous Purchase

Draeger, Inc. - DRA 6733171 - DT Aniline 0.5/a (10)

Items #: DRA 6733171

Dräger-Tubes - Aniline 0.5/a, Short-term Tubes, 10 tests per box, By Dräger, P/N 6733171 Dräger-Tubes - Aniline 0.5/a, Short-term Tubes, 10 tests per box, By Dräger, P/N 6733171 Application Range Standard Measuring Range: 0.5 to 10 ppm Number of Strokes n: 20 Time for Measurement: app. 4 min Standard Deviation: ± 15 to 20 % Colour Change: pale yellow -> pale green Ambient Operating Conditions - Temperature: 15 to 30 °C,Absolute Humidity: 7 to 12 mg H2O / L Reaction Principle - C6H5NH2 + CrVI -> CrIII + various oxidation products Cross Sensivity - When methyl aniline and aniline are present at the same time, it isimpossible to measure only the aniline concentration.Ethers, ketones, esters, aromatics and petrols are indicated as well butwith different sensitivities.High aniline concentrations will not be indicated.
Call For Availability
UOM : BX
$162.00


Add to Quote
Previous Purchase
Call For Availability
UOM : BX
$93.00


Add to Quote
Previous Purchase

Draeger, Inc. - DRA 8101161 - DT Butadiene 10/a-D (10)

Items #: DRA 8101161

Dräger Diffusion Tube, Carbon Monoxide 50/a-D, 10 to 300 ppm, 1.3 to 40 ppm, Draeger 8101161 Draeger Diffusion Tube, Ammonia 20/a-D, Standard Range of Measurement (20 degrees C, 1013 hPa) 10 to 300 ppm, Standard Range of Measurement for Maximum Period of Use (20 degrees C, 1013 hPa) 1.3 to 40 ppm, Dräger 8101161 Dräger Diffusion Tubes with Direct Indication Direct-reading Dräger diffusion tubes were developed especially for personal exposure monitoring. Benefits These systems do not require the use of a gas detector pump because the contaminant molecules pass into the tube by diffusion processes and in this manner are brought into contact with the reagent systems.
Call For Availability
UOM : ST
$126.00


Add to Quote
Previous Purchase

Draeger, Inc. - DRA 8101341 - DR Tetrahydrothiophene 1/b (5)

Items #: DRA 8101341

Product Specific Information; Dräger Tubes - Tetrahydrothiophene 1/b, Short Term Tubes, 5 tests per box, Draeger P/N 8101341 Standard Measuring Range : 1 to 10 ppm Number of Strokes (n) : 30 Time for Measurement : app. 15 min app. 10 min for ameasurement in natural gas. Standard Deviation : ± 15 to 20 % Colour Change : violet -> yellow brown Ambient Operating Conditions Temperature : 0 to 35 °C Absolute Humidity : < 30 mg H2O / L Reaction Principle a) Adsorption with H2S b) THT + KMnO4 -> yellow brown reaction product Cross Sensitivity Up to 10 ppm hydrogen sulphide is adsorbed in the pretube,causing a brown discoloration. It is impossible to measure tetrahydrothiophene in the presence ofmercaptans. Up to 100 ppm of olefines (e.g. ethene, propene) will cause thecolour of the indicating layer to become lighter, at higher concentrationsthe olefins cause plus errors. Up to 200 ppm methanol does not interfere.
Call For Availability
UOM : EA
$105.00


Add to Quote
Previous Purchase
Call For Availability
UOM : BX
$105.00


Add to Quote
Previous Purchase
  • « PREV
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • NEXT »