Search in Category
Sample Lines, Pumps, and Tubes
Search term required.
Filter Your Search
Browse Categories
Loading...
Sample Lines, Pumps, and Tubes
Viewing Page 24 of 25
(248 results)
Draeger, Inc. - DRA 8101531 - DT Sulfur Dioxide 50/b (10)
Items #:
DRA 8101531
Product Specific Information; Dräger Tubes - Sulphur Dioxide 50/b, Short Term Tubes, 10 tests per box, Draeger P/N 8101531
Standard Measuring Range : 400 to 8,000 ppm / 50 to 500 ppm
Number of Strokes (n) : 1 /10
Time for Measurement : app. 15 s / app. 3 min
Standard Deviation : ± 10 to 15 %
Colour Change : blue -> yellow
Ambient Operating Conditions
Temperature : 0 to 50 °C
Absolute Humidity : 1 to 15 mg H2O / L
Reaction Principle
SO2 + IO3– -> H2SO4 + I–
Cross Sensitivity
Hydrochloric acid is indicated in high concentrations. 10,000 ppmHydrochloric acid corresponds to an indication of 150 ppm sulphurdioxide.
No interference by:
500 ppm nitric oxide
100 ppm nitrogen dioxide
Draeger, Inc. - DRA 8101551 - DR Perchlorethylene 0,1/a (10)
Items #:
DRA 8101551
Product Specific Information; Dräger Tubes - Perchloroethylene 0.1/a, Short Term Tubes, 10 tests per box, Draeger P/N 8101551
Standard Measuring Range : 0.5 to 4 ppm / 0.1 to 1 ppm
Number of Strokes (n) :3 /9
Time for Measurement : app. 3 min / app. 9 min
Standard Deviation : ± 20 to 25 %
Colour Change : light grey -> blue
Ambient Operating Conditions
Temperature : 15 to 30 °C
Absolute Humidity : max. 30 mg H2O / L
Reaction Principle
a) CCI2=CCI2 + MnO4– -> CI2
b) CI2 + Diphenylbenzidine -> blue reaction product
Cross Sensitivity
Halogenated hydrocarbons and free halogens are indicated.Petroleum vapours reduce the perchloroethylene indication if theyexceed the following concentrations:
40 ppm at n=9
160 ppm at n=3
Draeger, Inc. - DRA 8103031 - DT Water vapour 3/a (10)
Items #:
DRA 8103031
Dräger Tubes - Water Vapor 3/a, Short Term Tubes, 10 tests per box, Draeger P/N 8103031
Product Specific Information; Dräger Tubes - Water Vapor 3/a, Short Term Tubes, 10 tests per box, Draeger P/N 8103031
Draeger, Inc. - DRA 8103491 - DT Chlorine Dioxide 0,025/a (10)
Items #:
DRA 8103491
Product Specific Information; Dräger-Tubes - Chlorine Dioxide, Short-term Tubes, 10 tests per box, By Dräger, P/N 8103491. Measuring Range 0.025/a - 3 ppm, 10/Box
Draeger, Inc. - DRA CH19501 - DT Nickel Tetracarbonyl 0.1/a (9)
Items #:
DRA CH19501
Product Specific Information; Dräger Tubes - Nickel Tetracarbonyl 0.1/a, Short Term Tubes, 9 tests per box, Draeger P/N CH19501
Standard Measuring Range : 0.1 to 1 ppm
Discoloration compared tocolour standard.
Number of Strokes (n) : 20
Time for Measurement : app. 5 min
Standard Deviation : ± 50 %
Colour Change : yellow -> pink
Ambient Operating Conditions
Temperature : 0 to 30 °C
Absolute Humidity : < 30 mg H2O / L
Reaction Principle
a) Ni(CO)4 + I2 -> NiI2 + 4 CO
b) NiI2 + Dimethylglyoxime -> pink coloured complex
Cross Sensitivity
Iron pentacarbonyl is indicated with a brown discoloration and witha lower sensitivity than nickel tetracarbonyl.Hydrogen sulphide and sulphur dioxide react with the iodine preparationand can suppress the nickel tetracarbonyl indication. TheInstructions for Use of this tube describe how the interference canbe quickly recognized.
Additional Information
After performing the required 20 pump strokes the reagent ampoulemust be broken and the liquid carefully drawn onto the indicationlayer using the pump.