Draeger, Inc. - DRA 8101531 - DT Sulfur Dioxide 50/b (10)
Items #:
DRA 8101531
Product Specific Information; Dräger Tubes - Sulphur Dioxide 50/b, Short Term Tubes, 10 tests per box, Draeger P/N 8101531
Standard Measuring Range : 400 to 8,000 ppm / 50 to 500 ppm
Number of Strokes (n) : 1 /10
Time for Measurement : app. 15 s / app. 3 min
Standard Deviation : ± 10 to 15 %
Colour Change : blue -> yellow
Ambient Operating Conditions
Temperature : 0 to 50 °C
Absolute Humidity : 1 to 15 mg H2O / L
Reaction Principle
SO2 + IO3– -> H2SO4 + I–
Cross Sensitivity
Hydrochloric acid is indicated in high concentrations. 10,000 ppmHydrochloric acid corresponds to an indication of 150 ppm sulphurdioxide.
No interference by:
500 ppm nitric oxide
100 ppm nitrogen dioxide
Draeger, Inc. - DRA 8103111 - DT Oil PN (10)
Items #:
DRA 8103111
Product Specific Information Dräger-Tubes - Oil 10 PN, Used with Aerotest, measuring range: 5 mg/m3, Used with Aerotest, 10 tubes per box, By Dräger, P/N 8103111.
• Used with Aerotest for compressed gas quality assurance
• Flow-through calibration
• Fast and simple to use
Order No. 8103111
Standard Measuring Range : 5 mg/m3
Draeger, Inc. - DRA 8103391 - Methyl Bromide 0.2/a Detector Tubes
Items #:
DRA 8103391
Product Specific Information; Dräger Tubes - Methyl Bromide 0.2/a, Short-term Tubes 10 tests per box, Draeger P/N 8103391
Standard Measuring Range: 0.2 to 2 ppm / 2 to 8 ppm
Number of Strokes n: 5 / 2
Time for Measurement: approx. 8 min. / approx. 4 min.
Standard Deviation: ± 15 to 20 %
Color Change: light color green
Ambient Operating Conditions - Temperature: 2 to 40 °C, Absolute Humidity: < 20 mg/L
Reaction Principle
CH3 Br + H2S2O7 + chromate Br2
Br2 + o-Tolidine green reaction product
Cross Sensitivity - Vinyl chloride or carbon tetrachloride: < 2 ppm no indication. Methylbromide cannot be measured in the presence of perchloroethyleneor trichloroethylene. Sulfuryl fluoride, phosphine, ethylene oxide,ammonia, hydrocyanic acid, chloropicrin and formaldehyde belowtheir AGW/TLV values are not indicated. Ethylene dibromide isindicated with 1.2 times its sensitivity.
Draeger, Inc. - DRA 8103421 - DT Chloropikrine 0.1/a (10)
Items #:
DRA 8103421
Product Specific Information; Dräger-Tubes - Chloropicrin 0.1/a, Short-term Tubes, 10 tests per box, By Dräger, P/N 8103421
Measuring Range 0.1 - 2 ppm, 5/Box
Draeger, Inc. - DRA 8103471 - DT Sulfuryl Fluoride 1/a (5)
Items #:
DRA 8103471
Product Features
• Simple to use
• Calibration not required
• Inexpensive and portable
• Wide variety of gases and vapors
• 70 years of proven technology
• Most Trusted Draeger-Tubes® have beenleading the way in gasdetection for over 60 years.
• Widest Range Over 200 different Draeger-Tubes® are available formeasuring over 500 gasesand vapors.
• Hassle-Free Operation No calibration, no lubrication,no special maintenance.Always ready to go.
Draeger, Inc. - DRA 8103491 - DT Chlorine Dioxide 0,025/a (10)
Items #:
DRA 8103491
Product Specific Information; Dräger-Tubes - Chlorine Dioxide, Short-term Tubes, 10 tests per box, By Dräger, P/N 8103491. Measuring Range 0.025/a - 3 ppm, 10/Box
Draeger, Inc. - DRA CH20301 - DT Carbon Dioxide 5%/a (10)
Items #:
DRA CH20301
Product Specific Information; Dräger-Tubes - Carbon Dioxide 5%/A, Short-term Tubes, 10 tests per box, By Dräger, P/N CH20301
Standard Measuring Range : 5 to 60 Vol.-%
Number of Strokes (n) : 1
Time for Measurement : app. 2 min
Standard Deviation : ± 10 to 15 %
Colour Change : white -> blue violet
Ambient Operating Conditions - Temperature : 0 to 40 °C, Absolute Humidity : max. 50 mg H2O / L
Reaction Principle - CO2 + N2H4 -> NH2-NH-COOH
Cross Sensitivity - Hydrogen sulphide in the TLV range does not interfere.In a range comparable to the calibrated range for carbon dioxide,sulphur dioxide is indicated with approximately the same sensitivity.
Product Group Information; EVER SINCE 1937 WHEN WE INTRODUCED OUR FIRST DETECTOR TUBE, DRAEGERHAS BEEN THE WORLD LEADER IN THE ANALYSIS OF GASES AND VAPORS IN THEINDUSTRIAL WORKPLACE. OVER THE YEARS WE HAVE DEVELOPED MORE TUBESAND DETECTION DEVICES FOR MORE APPLICATIONS THAN ANYONE ELSE! OURLEADING EDGE TECHNOLOGY HAS KEPT US ON THE FOREFRONT OF COLORIMETRICDETECTOR TUBES THUS PROVIDING THE MOST ACCURATE AND SPECIFIC RESULTSAVAILABLE.
Product Features
• Simple to use
• Calibration not required
• Inexpensive and portable
• Wide variety of gases and vapors
• 70 years of proven technology
• Most Trusted Draeger-Tubes® have beenleading the way in gasdetection for over 60 years.
• Widest Range Over 200 different Draeger-Tubes® are available formeasuring over 500 gasesand vapors.
• Hassle-Free Operation No calibration, no lubrication,no special maintenance.Always ready to go.