Browse Categories

SCBA (Self Contained Breathing Apparatus)

Respiratory Protection/SCBA (Self Contained Breathing Apparatus) 
Viewing Page 6 of 62 (620 results)

AIR SYSTEMS INTERNATIONAL - AIR BB30-COAAP - 30 CFM BREATHER BOX W/ AUTO-AIR FEATURE

Items #: AIR BB30-COAAP

Pneumatic system features a reserve air trigger at 60 psig and / or loss of electrical power, it automatically switches to reserve air cylinder (or cylinders). Local & optional remote alarms will signal workers that their primary air system is in failure & has switched to a back up air supply system. If IDLH work environments exist, the Auto-Air Breather Box option should be considered. The Auto-Air filtration system was developed to provide Grade-D breathing air with full automatic reserve air in the event of either electrical failure or reduced pressure from the main air source while working in hazardous environments. Reserve air activation occurs at 60 psi and/or loss of electrical supply, the system automatically switches to the reserve air cylinder(s). Local and optional remote alarms signal the workers that the primary air system has failed and has switched to the back-up air system Features 30 cfm Intrinsically Safe Auto-Air TM Breather BoxTM (48 cfm flow capacity) - 2 couplings CSA approved Class I, Div. 1, groups D and C Filtration efficiency 99.99 percent @ 0.01 micron Fully Automatic Reserve Air System for Work in IDLH Environments Note: IDLH conditions require the use of a pressure demand respirator with at least a 5 minute escape cylinder The primary air line connection is attached from the compressor to the Auto-Air Breather Box A reserve air line is attached from a single or bank of air cylinders based on the required egress duration and number of workers using the system The system can be tested prior to each use to ensure proper function of the Auto-Air system Always size the reserve air systems to allow an adequate safety factor for all workers to egress the environment Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge
Call For Availability
UOM : EA
$3,669.75


Add to Quote
Previous Purchase
Call For Availability
UOM : EA
$5,559.75


Add to Quote
Previous Purchase

AIR SYSTEMS INTERNATIONAL - AIR BB50-CO4R - 50 CFM BREATHER BOX FILTRATION SYSTEM

Items #: AIR BB50-CO4R

It also has standard filter change indicators for for all 3 filtration stages. The Breather Box is a portable Grade-D filtration system designed to provide breathing air for a specific number of workers. The system filters incoming air from a compressor to provide respirator users with Grade-D quality air and monitors for CO. The first stage element filters bulk water and particulate and has an auto drain. The second stage coalescing filter eliminates atomized oils, mists, ultra-fine particulates, and has an auto drain. The third stage filter removes organic vapors and odors and has a manual drain. Filter change indicators are standard on all three stages of filtration. Filtration efficiency is 99.99% @ .01 micron. All Breather Boxes are designed to be used in the upright and closed position to prevent internal contamination. The standard carbon monoxide (CO) airline monitor operates on 8-16 volt DC, or 115 VAC for continuous air monitoring. An external audible alarm and light signals the workers of high CO content. Point-of-Attachment (POA) boxes can extend respirator usage beyond 300 feet. Features 79 CFM flow capacity 4 couplings 4 independent regulators and pressure gauges 99.99 percent filtration efficiency @ .01 micron 9 Volt disposable batteries External light & alarm signals Remote alarm jack Canadian Z180.1 BS-EN 12021:1999 OSHA 1910.134 Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge
Call For Availability
UOM : EA
$2,485.00


Add to Quote
Previous Purchase

AIR SYSTEMS INTERNATIONAL - AIR BB50-COAA - 50 CFM AUTO-AIR BREATHER BOX

Items #: AIR BB50-COAA

Standard electric system features a reserve air trigger at 60 psig and / or loss of electrical power, it automatically switches to reserve air cylinder (or cylinders). Local & optional remote alarms will signal workers that their primary air system is in failure & has switched to a back up air supply system. If IDLH work environments exist, the Auto-Air Breather Box option should be considered. The Auto-Air filtration system was developed to provide Grade-D breathing air with full automatic reserve air in the event of either electrical failure or reduced pressure from the main air source while working in hazardous environments. Reserve air activation occurs at 60 psi and/or loss of electrical supply, the system automatically switches to the reserve air cylinder(s). Local and optional remote alarms signal the workers that the primary air system has failed and has switched to the back-up air system Features 50 cfm Auto-Air Breather Box - (79 cfm flow capacity) - 4 couplings Filtration efficiency 99.99 percent @ 0.01 micron Fully Automatic Reserve Air System for Work in IDLH Environments Note: IDLH conditions require the use of a pressure demand respirator with at least a 5 minute escape cylinder The primary air line connection is attached from the compressor to the Auto-Air Breather Box A reserve air line is attached from a single or bank of air cylinders based on the required egress duration and number of workers using the system The system can be tested prior to each use to ensure proper function of the Auto-Air system Always size the reserve air systems to allow an adequate safety factor for all workers to egress the environment Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge
Call For Availability
UOM : EA
$3,195.00


Add to Quote
Previous Purchase

AIR SYSTEMS INTERNATIONAL - AIR BB50-COAAP - 50 CFM BREATHER BOX W/ AUTO-AIR FEATURE

Items #: AIR BB50-COAAP

Pneumatic system features a reserve air trigger at 60 psig and / or loss of electrical power, it automatically switches to reserve air cylinder (or cylinders). Local & optional remote alarms will signal workers that their primary air system is in failure & has switched to a back up air supply system. If IDLH work environments exist, the Auto-Air Breather Box option should be considered. The Auto-Air filtration system was developed to provide Grade-D breathing air with full automatic reserve air in the event of either electrical failure or reduced pressure from the main air source while working in hazardous environments. Reserve air activation occurs at 60 psi and/or loss of electrical supply, the system automatically switches to the reserve air cylinder(s). Local and optional remote alarms signal the workers that the primary air system has failed and has switched to the back-up air system Features 50 cfm Intrinsically Safe Auto-Air TM Breather BoxTM (79 cfm flow capacity) - 4 couplings CSA approved Class I, Div. 1, groups D and C Filtration efficiency 99.99 percent @ 0.01 micron Fully Automatic Reserve Air System for Work in IDLH Environments Note: IDLH conditions require the use of a pressure demand respirator with at least a 5 minute escape cylinder The primary air line connection is attached from the compressor to the Auto-Air Breather Box A reserve air line is attached from a single or bank of air cylinders based on the required egress duration and number of workers using the system The system can be tested prior to each use to ensure proper function of the Auto-Air system Always size the reserve air systems to allow an adequate safety factor for all workers to egress the environment Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge
Call For Availability
UOM : EA
$3,495.00


Add to Quote
Previous Purchase

AIR SYSTEMS INTERNATIONAL - AIR BB50-COIS - 50 CFM INTRINSICALLY SAFE BREATHER BOX

Items #: AIR BB50-COIS

The 1st stage element will filter bulk water & particulates, the 2nd stage coalescing filter will remove atomized oils & ultra-fine particulates & the 3rd stage will remove sorganic vapors & odors. A standard airline monitor operates with 9 Volt batteries & an audible alarm warns workers to high carbon monoxide concentrations. Features Intrinsically safe Flow capacity 79 CFM Filtration efficiency of 99.99 percent @ 0.01 micron (Optional) Point of attachment boxes can extend respiratory usage to over 300 ft. 1/4 inch hansen or schrader type fittings Engineered to be used in closed & upright positions to prevent internal contamination 9 Volt batteries, 8 - 16 Volts DC or 115 Volts AC for continuous air monitoring External audible alarm & light OSHA 1910.134 compliant Canadian Z180.1 BS-EN 12021:1999
Call For Availability
UOM : EA
$2,195.00


Add to Quote
Previous Purchase

AIR SYSTEMS INTERNATIONAL - AIR BB75-C - REPLACEMENT COALESCING FILTER - 75 CFM

Items #: AIR BB75-C

Coalescing C-Filter Element, For Use With Mfr. Model Number BB75-CO, Fits Brand Air Systems
Call For Availability
UOM : EA
$131.25


Add to Quote
Previous Purchase

AIR SYSTEMS INTERNATIONAL - AIR BB75-CO - 75 CFM BREATHER BOX FILTRATION SYSTEM

Items #: AIR BB75-CO

Air Systems International Replacement Filter Kit includes an "A", "C" and "D" replacement filters and is designed for BB75-CO series models.
Call For Availability
UOM : EA
$2,395.00


Add to Quote
Previous Purchase

AIR SYSTEMS INTERNATIONAL - AIR BB75-COPM - 75 CFM FILTRATION PANEL W/CO MONITOR

Items #: AIR BB75-COPM

The system filters compressor air to provide respirator users with Grade-D quality air. The first stage element filters bulk water and particulate, the second stage coalescing filter removes atomized oils and ultra-fine particulate, and the third stage removes organic vapors and odors. Filter change indicators are standard on all three filtration stages. Filtration efficiency is 99.99% @ .01 microns. A built-in carbon monoxide monitor operates on 115 VAC, or 8-16 VDC for continuous detection. A high intensity audible alarm and light signals the workers of high CO content in their breathing air. A 115 VAC electrical conduit box is provided as standard to provide AC power in and connection for AC powered remote alarms. Filtration components are mounted on powder coated steel panel. Features 75 CFM (97 CFM flow capacity) CO carbon monoxide monitor 99.99 percent filtration efficiency @ .01 microns 6 couplings or NPT outlet Integrated carbon monoxide (CO) monitor uses 115 Volts AC or 8 to 16 Volts DC for continuous detection Audible high intensity alarm & light will signal workers to high CO in breathing air supply All portable and fixed breathing air filtration systems meet or exceed OSHA 1910.134, Canadian Z180.1 Breathing Air Standards and British Standard BS-EN 12021:1999 “RESPIRATORY PROTECTIVE DEVICES” All filtration units are designed to flow the NIOSH maximum capacity per worker Air Systems provides at NO CHARGE your first lab certified air quality test of your new breathing air filtration device Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge.
Call For Availability
UOM : EA
$2,395.00


Add to Quote
Previous Purchase

AIR SYSTEMS INTERNATIONAL - AIR BBK-10 - CALIBRATION KIT WITH 10PPM GAS

Items #: AIR BBK-10

Air Systems BBK-10 is a calibration kit for Canadian CO monitors. Features 17 Liter disposable cylinders Airline monitor calibration should occur monthly or when monitor accuracy is in question Use only Air Systems gas concentration cylinders or inaccuracies in calibration may occur Calibration kit - 10 ppm CO for Canada Zero air Regulator Tubing Hard case WARNING: This product can expose you to chemicals including Carbon Monoxide, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, visit www.P65Warnings.ca.gov
Call For Availability
UOM : KT
$220.00


Add to Quote
Previous Purchase
  • « PREV
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • NEXT »