Search in Category
SCBA (Self Contained Breathing Apparatus)
Search term required.
Filter Your Search
Brand
No Filtered Results...
Browse Categories
Loading...
SCBA (Self Contained Breathing Apparatus)
Viewing Page 44 of 62
(620 results)
AIR SYSTEMS INTERNATIONAL - AIR BB50-CO2PM - BB50-CO FILTRATION PANEL, CO2-91 MONITO
Items #:
AIR BB50-CO2PM
The system filters compressor air to provide respirator users with Grade-D quality air. The first stage element filters bulk water and particulate, the second stage coalescing filter removes atomized oils and ultra-fine particulate, and the third stage removes organic vapors and odors. Filter change indicators are standard on all three filtration stages. Filtration efficiency is 99.99% @ .01 microns. A built-in intrinsically safe carbon monoxide monitor operates on 115 VAC, or 8-16 VDC for continuous detection. A high intensity audible alarm and light signals the workers of high CO content in their breathing air. A 115 VAC electrical conduit box is provided as standard to provide AC power in and connection for AC powered remote alarms. Filtration components are mounted on powder coated steel panel.
Features
50 CFM (79 CFM flow capacity)
O2 oxygen & CO carbon monoxide monitor
99.99 percent filtration efficiency @ .01 microns
4 couplings or NPT outlet
Integrated carbon monoxide (CO) monitor uses 115 Volts AC or 8 to 16 Volts DC for continuous detection
Audible high intensity alarm & light will signal workers to high CO in breathing air supply
All portable and fixed breathing air filtration systems meet or exceed OSHA 1910.134, Canadian Z180.1 Breathing Air Standards and British Standard BS-EN 12021:1999 “RESPIRATORY PROTECTIVE DEVICES”
All filtration units are designed to flow the NIOSH maximum capacity per worker
Air Systems provides at NO CHARGE your first lab certified air quality test of your new breathing air filtration device
Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge.
AIR SYSTEMS INTERNATIONAL - AIR BB50-CO4R - 50 CFM BREATHER BOX FILTRATION SYSTEM
Items #:
AIR BB50-CO4R
It also has standard filter change indicators for for all 3 filtration stages.
The Breather Box is a portable Grade-D filtration system designed to provide breathing air for a specific number of workers. The system filters incoming air from a compressor to provide respirator users with Grade-D quality air and monitors for CO.
The first stage element filters bulk water and particulate and has an auto drain. The second stage coalescing filter eliminates atomized oils, mists, ultra-fine particulates, and has an auto drain. The third stage filter removes organic vapors and odors and has a manual drain. Filter change indicators are standard on all three stages of filtration. Filtration efficiency is 99.99% @ .01 micron. All Breather Boxes are designed to be used in the upright and closed position to prevent internal contamination.
The standard carbon monoxide (CO) airline monitor operates on 8-16 volt DC, or 115 VAC for continuous air monitoring. An external audible alarm and light signals the workers of high CO content. Point-of-Attachment (POA) boxes can extend respirator usage beyond 300 feet.
Features
79 CFM flow capacity
4 couplings
4 independent regulators and pressure gauges
99.99 percent filtration efficiency @ .01 micron
9 Volt disposable batteries
External light & alarm signals
Remote alarm jack
Canadian Z180.1
BS-EN 12021:1999
OSHA 1910.134
Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge
AIR SYSTEMS INTERNATIONAL - AIR BB50-COAA - 50 CFM AUTO-AIR BREATHER BOX
Items #:
AIR BB50-COAA
Standard electric system features a reserve air trigger at 60 psig and / or loss of electrical power, it automatically switches to reserve air cylinder (or cylinders). Local & optional remote alarms will signal workers that their primary air system is in failure & has switched to a back up air supply system.
If IDLH work environments exist, the Auto-Air Breather Box option should be considered. The Auto-Air filtration system was developed to provide Grade-D breathing air with full automatic reserve air in the event of either electrical failure or reduced pressure from the main air source while working in hazardous environments. Reserve air activation occurs at 60 psi and/or loss of electrical supply, the system automatically switches to the reserve air cylinder(s). Local and optional remote alarms signal the workers that the primary air system has failed and has switched to the back-up air system
Features
50 cfm Auto-Air Breather Box - (79 cfm flow capacity) - 4 couplings
Filtration efficiency 99.99 percent @ 0.01 micron
Fully Automatic Reserve Air System for Work in IDLH Environments
Note: IDLH conditions require the use of a pressure demand respirator with at least a 5 minute escape cylinder
The primary air line connection is attached from the compressor to the Auto-Air Breather Box A reserve air line is attached from a single or bank of air cylinders based on the required egress duration and number of workers using the system
The system can be tested prior to each use to ensure proper function of the Auto-Air system
Always size the reserve air systems to allow an adequate safety factor for all workers to egress the environment
Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge
AIR SYSTEMS INTERNATIONAL - AIR BB50-COAAP - 50 CFM BREATHER BOX W/ AUTO-AIR FEATURE
Items #:
AIR BB50-COAAP
Pneumatic system features a reserve air trigger at 60 psig and / or loss of electrical power, it automatically switches to reserve air cylinder (or cylinders). Local & optional remote alarms will signal workers that their primary air system is in failure & has switched to a back up air supply system.
If IDLH work environments exist, the Auto-Air Breather Box option should be considered. The Auto-Air filtration system was developed to provide Grade-D breathing air with full automatic reserve air in the event of either electrical failure or reduced pressure from the main air source while working in hazardous environments. Reserve air activation occurs at 60 psi and/or loss of electrical supply, the system automatically switches to the reserve air cylinder(s). Local and optional remote alarms signal the workers that the primary air system has failed and has switched to the back-up air system
Features
50 cfm Intrinsically Safe Auto-Air TM Breather BoxTM (79 cfm flow capacity) - 4 couplings
CSA approved Class I, Div. 1, groups D and C
Filtration efficiency 99.99 percent @ 0.01 micron
Fully Automatic Reserve Air System for Work in IDLH Environments
Note: IDLH conditions require the use of a pressure demand respirator with at least a 5 minute escape cylinder
The primary air line connection is attached from the compressor to the Auto-Air Breather Box A reserve air line is attached from a single or bank of air cylinders based on the required egress duration and number of workers using the system
The system can be tested prior to each use to ensure proper function of the Auto-Air system
Always size the reserve air systems to allow an adequate safety factor for all workers to egress the environment
Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge
AIR SYSTEMS INTERNATIONAL - AIR BB50-COIS - 50 CFM INTRINSICALLY SAFE BREATHER BOX
Items #:
AIR BB50-COIS
The 1st stage element will filter bulk water & particulates, the 2nd stage coalescing filter will remove atomized oils & ultra-fine particulates & the 3rd stage will remove sorganic vapors & odors. A standard airline monitor operates with 9 Volt batteries & an audible alarm warns workers to high carbon monoxide concentrations.
Features
Intrinsically safe
Flow capacity 79 CFM
Filtration efficiency of 99.99 percent @ 0.01 micron
(Optional) Point of attachment boxes can extend respiratory usage to over 300 ft.
1/4 inch hansen or schrader type fittings
Engineered to be used in closed & upright positions to prevent internal contamination
9 Volt batteries, 8 - 16 Volts DC or 115 Volts AC for continuous air monitoring
External audible alarm & light
OSHA 1910.134 compliant
Canadian Z180.1
BS-EN 12021:1999
AIR SYSTEMS INTERNATIONAL - AIR BB50-COO2 - 50 CFM BREATHER BOX FILTRATION SYSTEM
Items #:
AIR BB50-COO2
It also has standard filter change indicators for for all 3 filtration stages.
The Breather Box is a portable Grade-D filtration system designed to provide breathing air for a specific number of workers. The system filters incoming air from a compressor to provide respirator users with Grade-D quality air and monitors for CO and O2.
The first stage element filters bulk water and particulate and has an auto drain. The second stage coalescing filter eliminates atomized oils, mists, ultra-fine particulates, and has an auto drain. The third stage filter removes organic vapors and odors and has a manual drain. Filter change indicators are standard on all three stages of filtration. Filtration efficiency is 99.99% @ .01 micron. All Breather Boxes are designed to be used in the upright and closed position to prevent internal contamination.
The standard carbon monoxide (CO) airline monitor operates on 8-16 volt DC, or 115 VAC for continuous air monitoring. An external audible alarm and light signals the workers of high CO content. Point-of-Attachment (POA) boxes can extend respirator usage beyond 300 feet.
Features
CO and O2 monitoring
50 cfm Breather Box - (79 cfm flow capacity)
4 couplings
99.99 percent filtration efficiency @ .01 micron
External light & alarm signals
Remote alarm jack
Canadian Z180.1
BS-EN 12021:1999
OSHA 1910.134
Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge
Air Systems International - AIR BB50-COPM - Air Filtration Fixed System, 50 cfm
Items #:
AIR BB50-COPM
Brand: Air Systems International
This permanent mount air filtration system is designed to deliver breathing air to a specific amount of workers. This system will filter compressor air in order to provide respirators with Grade D quality breathing air. The 1st stage element will filter bulk water & particulates, the 2nd stage coalescing filter will remove atomized oils & ultra-fine particulates & the 3rd stage will removes organic vapors & odors.
Features
4 Worker capacity
Filter change indicator included for all 3 filtration stages
99.99 percent filtration efficiency @ .01 microns
Integrated carbon monoxide (CO) monitor uses 9 Volts DC, 115 Volts AC or 8 to 16 Volts DC for continuous detection
Audible high intensity alarm & light will signal workers to high CO in breathing air supply
OSHA 1910.134 compliant
79 CFM Air Flow
125 PSI
AIR SYSTEMS INTERNATIONAL - AIR BB50-HTAAP - INTRINSICALLY SAFE PNEUMATIC AUTO-AIR
Items #:
AIR BB50-HTAAP
Operates with 2400 - 5000 PSI cylinders and is suitable for hazardous locations.
Intrinsically Safe (IS) CO Monitors are CSA Approved for Class I, Division 1, Groups C and D Environments. Units are DC 9-Volt Operation Only
Features
50 cfm Intrinsically Safe Auto-Air Cart Small - (79 cfm flow capacity)
4 couplings
Please specify 1/4” Hansen style or Schrader style fittings when ordering
Other fittings available for an additional charge
Holds two 60 CF air cylinders
2 year warranty on sensor and monitor
Applications
Refineries
Chemical and Pharmaceutical manufacturing
Refueling applications
Tank cleaning
Decon required situations
Grain silo entry
All lights and remote alarms are pneumatically operated and spark free. The intrinsically safe CO monitor is CSA approved and operates on 9-volt DC batteries only.
AIR SYSTEMS INTERNATIONAL - AIR BB50COAAPM - 50CFM FILTRATION PANEL W/AUTO AIR
Items #:
AIR BB50COAAPM
The system filters compressor air to provide respirator users with Grade-D quality air. The first stage element filters bulk water and particulate, the second stage coalescing filter removes atomized oils and ultra-fine particulate, and the third stage removes organic vapors and odors. Filter change indicators are standard on all three filtration stages. Filtration efficiency is 99.99% @ .01 microns. A built-in intrinsically safe carbon monoxide monitor operates on 115 VAC, or 8-16 VDC for continuous detection. A high intensity audible alarm and light signals the workers of high CO content in their breathing air. A 115 VAC electrical conduit box is provided as standard to provide AC power in and connection for AC powered remote alarms. Filtration components are mounted on powder coated steel panel.
Features
50 CFM Grade-D Auto-Air breathing air panel (79 CFM flow capacity)
CO carbon monoxide monitor
99.99 percent filtration efficiency @ .01 microns
4 couplings or NPT outlet
Integrated carbon monoxide (CO) monitor uses 115 Volts AC or 8 to 16 Volts DC for continuous detection
Audible high intensity alarm & light will signal workers to high CO in breathing air supply
All portable and fixed breathing air filtration systems meet or exceed OSHA 1910.134, Canadian Z180.1 Breathing Air Standards and British Standard BS-EN 12021:1999 “RESPIRATORY PROTECTIVE DEVICES”
All filtration units are designed to flow the NIOSH maximum capacity per worker
Air Systems provides at NO CHARGE your first lab certified air quality test of your new breathing air filtration device
Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge.