Browse Categories

SCBA (Self Contained Breathing Apparatus)

Respiratory Protection/SCBA (Self Contained Breathing Apparatus) 
Viewing Page 15 of 62 (620 results)

Air Systems International - AIR CO2-91 - Dual Oxygen & Carbon Monoxide Monitor

Items #: AIR CO2-91
Brand: Air Systems International

Dual Oxygen & Carbon Monoxide Monitor Replacement part for BB50-COO2 series breather boxes
Call For Availability
UOM : EA
$1,569.75


Add to Quote
Previous Purchase
Call For Availability
UOM : EA
$1,895.00


Add to Quote
Previous Purchase

AIR SYSTEMS INTERNATIONAL - AIR CO2-91PM - CO2 MONITOR COMPLETE FOR PANEL

Items #: AIR CO2-91PM

CO Monitor Specifications: Calibration: Less than 2 minutes Monitor display: LCD 3-digit readout Temperature range: 4 to 113 degrees F (-20 to 45 degrees C) Accuracy: +1- 1 % of full scale Monitor range: 0-200 ppm CO (15-23% for optional 0,) Pressure range: 1-3 psi, flow 50-100cc Response: 90% of full scale in 10 seconds Sensor type: 3-electrode electrochemical with bias voltage Humidity range: 5% to 95% relative humidity Warranty: 2 years on entire unit and CO sensor (1 year on oxygen sensor) Alarm set point: 10ppm CO (5 ppm Canada) Voltage operation: 115 VAC, dual 9-volt DC battery, or 8-1 6 volt DC Test circuitry: manual push-to-test for sensor operation and alarms Shielding: internal RFI/EMI circuitry, aluminum case Warning indicators: low battery (amber), normal operation (green), high CO level (red) (LED indicators vary with model ordered) Output signals (standard): DC output on portables, AC output on panel versions Monitor case housing: black anodized aluminum Control panel standard features: inlet gas quick connect coupling, auxiliary 12 VDC jack, on/off/test switch, auxiliary/remote alarm jack, 115 VAC jack Dimensions: 7.0" Lx 2.75" H x 5.1" W Weight: 2.1 lbs.
Call For Availability
UOM : EA
$1,989.75


Add to Quote
Previous Purchase

AIR SYSTEMS INTERNATIONAL - AIR COMP-3EA - TWIN AIR COMPRESSOR PKG. W/ AUTO-AIR

Items #: AIR COMP-3EA

This compressor system is designed to provide automatic back-up air for up to 3 workers in the event of compressor failure. An optional 60 or 87cf cylinder can be installed on the compressor frame to provide additional egress air. The package consists of the Auto-Air Breather Box BB30-COAA, the TA-3EA compressor supplied with a CGA-347 high pressure reducing regulator, primary and secondary hoses. NIOSH requires the use of a 5 minute airline escape respirator when working in IDLH environments. The Auto-Air feature does not replace the NIOSH requirement, however, some work environments may require longer than a 5 minute airline hip bottle to safely egress the hazardous area. This compressor isnot designed for use with constant flow respirators or Vortex cooling tubes.
Call For Availability
UOM : EA
$11,865.00


Add to Quote
Previous Purchase

AIR SYSTEMS INTERNATIONAL - AIR H-6-3S - Breathing Air Hose 3/8in, 6ft,

Items #: AIR H-6-3S

6 FT. 3/8” BREATHING AIR HOSE, AIR SYSTEMS INTERNATIONAL
Call For Availability
UOM : EA
$63.00


Add to Quote
Previous Purchase

AIR SYSTEMS INTERNATIONAL - AIR HPM-3H - 3-OUTLET MANIFOLD WITH 1/4 HANSEN FTGS.

Items #: AIR HPM-3H

Air Systems, HPM-3H, 3 Outlet Manifold With 1/4 Hansen FTGS
Call For Availability
UOM : EA
$175.00


Add to Quote
Previous Purchase

AIR SYSTEMS INTERNATIONAL - AIR HPM-4H - 4-OUTLET MANIFOLD WITH 1/4 HANSEN FTGS.

Items #: AIR HPM-4H

Air Systems, HPM-4H, 4 Outlet Manifold With 1/4 Hansen FTGS
Call For Availability
UOM : EA
$220.00


Add to Quote
Previous Purchase

AIR SYSTEMS INTERNATIONAL - AIR HPM-5H - 5-OUTLET MANIFOLD WITH 1/4 HANSEN FTGS.

Items #: AIR HPM-5H

Air Systems, HPM-5H, 5 Outlet Manifold With 1/4 Hansen FTGS
Call For Availability
UOM : EA
$250.00


Add to Quote
Previous Purchase

AIR SYSTEMS INTERNATIONAL - AIR MACK-1 - 4-OUTLET H/P AIR DISTRIBUTION BOX

Items #: AIR MACK-1

This Command kit has a 4 manifold 5000 PSIG regulator and dual high pressure cylinder whips. It also has a low pressure alarm whistle & DC lamp which illuminates the case's interior. The CGA-347 high pressure inlet that enables uninterrupted operation for portable breathing air cylinders and large air storage cylinder banks that are truck mounted. One or two SCBA cylinders provide air to the system. A CGA-347 high pressure inlet is also provided to allow continuous operation from truck mounted air cylinders. A low pressure regulator provides 0-125 psi air to a four outlet respirator manifold. A low pressure alarm whistle and a DC lamp to illuminate the case interior are provided as standard. The MACK units have been designed as a series of portable air distribution boxes to meet the most demanding air handling needs of the Fire, Rescue, and Emergency Response industry. Designed and tested by professional firefighters to meet the rigorous industry and NFPA requirements. Manufactured to provide emergency low pressure breathing air from either SCBA cylinders or from a bank of large storage cylinders located on department vehicles. Features Air Distribution for Breathing, Filling, and Rescue Applications Air outlet pressure adjustment from 0 -125 PSI Suitable for hazardous locations and meets NFPA requirements 4 outlet manifold 5000 PSI regulator 2 - high pressure cylinder whips High pressure inlet port
Call For Availability
UOM : EA
$1,695.00


Add to Quote
Previous Purchase

AIR SYSTEMS INTERNATIONAL - AIR MACK-2 - AIR DISTRIBUTION BOX W/FILL REG. ASSY.

Items #: AIR MACK-2

This Command kit has a 4 manifold 5000 PSIG regulator and dual high pressure cylinder whips. It also has a low pressure alarm whistle & DC lamp which illuminates the case's interior. The CGA-347 high pressure inlet that enables uninterrupted operation for portable breathing air cylinders and large air storage cylinder banks that are truck mounted. One or two SCBA cylinders provide air to the system. A CGA-347 high pressure inlet is also provided to allow continuous operation from truck mounted air cylinders. A low pressure regulator provides 0-125 psi air to a four outlet respirator manifold. A low pressure alarm whistle and a DC lamp to illuminate the case interior are provided as standard. The MACK units have been designed as a series of portable air distribution boxes to meet the most demanding air handling needs of the Fire, Rescue, and Emergency Response industry. Designed and tested by professional firefighters to meet the rigorous industry and NFPA requirements. Manufactured to provide emergency low pressure breathing air from either SCBA cylinders or from a bank of large storage cylinders located on department vehicles. Features Air Distribution for Breathing, Filling, and Rescue Applications Air outlet pressure adjustment from 0 -125 PSI Suitable for hazardous locations and meets NFPA requirements 4 outlet manifold 5000 PSI regulator 2 - high pressure cylinder whips High pressure fill regulator 1 fill whip (optional 2nd fill whip available for installation) High pressure inlet port
Call For Availability
UOM : EA
$2,595.00


Add to Quote
Previous Purchase
  • « PREV
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • NEXT »